LR8400 ½Ã¸®Áî | |
°·ÂÇÑ ¼º´É°ú È޴뼺À» µ¿½Ã¿¡... | |
Á¦Ç°¹øÈ£ | LR8400 ½Ã¸®Áî |
---|---|
Á¦Ç°¸í | MEMORY HiLOGGER |
Á¦Ç°ºÐ·ù | ·¹ÄÚ´õ |
![]() ![]() ![]() |
![]() | A4 »çÀÌÁîÀÇ ·Î°Å, Ç¥ÁØ 30ch. ÃÖ´ë 60ch »ç¿ë°¡´É(¿É¼Ç ÀåÂø½Ã) | |
![]() | ´ë¿ë·® ¸Þ¸ð¸®¿Í µ¥ÀÌŸ º¸È£±â´ÉÀ¸·Î Àå½Ã°£ÀÇ µ¥ÀÌŸÀúÀå¿¡ ¾È¼º¸ÂÃã | |
![]() | ¿Âµµ,½Àµµ,¾Ð·ÂµîÀÇ È¯°æº¯È¿¡ ÀÇÇÑ ÇÇÃøÁ¤¹°ÀÇ ÀúÇ×°ª º¯È ±â·Ï°¡´É. | |
![]() | 10m secÀÇ °í¼Ó»ùÇøµ | |
![]() | USB ¸Þ¸ð¸® »ç¿ë°¡´É. | |
Analog input UNIVERSAL UNIT LR8501 Actual functionality will depend on combination of units installed Note: Isolated from each channel to chassis | [No. of channels] 15 analog channels; isolated scanning method input (4 terminals: push-button type) [Voltage] 10 mV to 100 V, 1-5 V f.s. 10 ranges, Max. resolution: 500 nV Note: Isolated between channels and from each channel to chassis [Temperature: Thermocouples] -200¡ÆC to 2000¡ÆC (depends on sensor), 3 ranges (K, J, E, T, N, R, S, B, W), Max. resolution 0.01¡ÆC Note: Isolated between channels and from each channel to chassis [Temperature: Pt 100, JPt 100 sensor] -200¡ÆC to 100%¡ÆC, 3 ranges, Max. resolution 0.01¡ÆC Note: Not isolated between channels [Resistance] 10 ¥Ø to 200 ¥Ø f.s. 4 ranges, Max. resolution 0.5 m¥Ø Note: Not isolated between channels [Humidity] 100 % rh f.s. 5.0 to 95.0 % rh (when using Z2000), resolution 0.1 % rh Note: Not isolated between channels nor from each channel to chassis [Max. rated voltage between isolated input channels] 300 V DC [Max. allowable input] ¡¾100 V DC [Max. rated voltage from isolated terminals to ground] 300 V AC, DC |
Analog input VOLTAGE/TEMP UNIT LR8500 Actual functionality will depend on combination of units installed Note: Isolated from each channel to chassis | [No. of channels] 15 analog channels; isolated scanning method input (2 terminals: M3 screw type) [Voltage] 10 mV to 100 V, 1-5 V f.s. 10 ranges, Max. resolution: 500 nV Note: Isolated between channels and from each channel to chassies [Temperature: Thermocouples] -200¡ÆC to 2000¡ÆC (depends on sensor), 3 ranges (K, J, E, T, N, R, S, B, W), Max. resolution 0.01¡ÆC Note: Isolated between channels and from each channel to chassies [Temperature: Pt 100, JPt 100 sensor] [Resistance] not available [Humidity] 100 % rh f.s. 5.0 to 95.0 % rh (when using Z2000), resolution 0.1 % rh Note: Not isolated between channels nor from each channel to chassies [Max. rated voltage between isolated input channels] 250 V DC [Max. allowable input] ¡¾100 V DC [Max. rated voltage from isolated terminals to ground] 300 V AC, DC Caution: Max. voltage from terminals to ground without damage |
Pulse, Digital input | [No. of channels] 8 channels, pulse / digital selectable for each channel, M3 screw terminal, not isolated, common ground [Pulse totalization] 0 to 1000 M pulse, 1 range (No-voltage 'a' contact; normally open, open collector or voltage input), Max. resolution 1 pulse [Pulse revolutions] 0 to 5000 /n (r/s) f.s. 1 range (same as Pulse totalization input signal condition), resolution 1/n (r/s) Note: "n" is the number of sensor output pulses per revolution, 1 to 1000 [Digital input] Record logical "1" or "0" at each sampling [Max. rated voltage between input channels] Not isolated [Max. allowable input] 0 to 50 V |
Recording intervals | 10 ms to 50 ms, 100 ms to 1 hour, 19 selections (All input channels are scanned at high speed during every recording interval) Note: limited by using channels at 10 ms to 50 ms interval |
Digital filter | Select from OFF/ 50 Hz/ 60 Hz (the cut-off frequency is automatically set) |
Data storage | Internal memory: 8 M-words, Data storage media: CF card or USB memory (Only data recorded to a genuine HIOKI CF card is guaranteed) |
LAN interface | 100BASE-TX, Functions: Data acquisition using bundled software or PC commands, FTP server, FTP client, HTTP server function, or E-mail system Note: LAN communication support planned from software Ver. 1.20 |
USB interface | USB 2.0 High-speed capable, series mini-B receptacle Functions: Data acquisition using bundled software or PC commands, Transfer data from the CF card to a PC via USB drive mode Note: Data transfer not possible from USB memory sticks |
Display device | 5.7 inch TFT color liquid crystal display (640 ¡¿ 480 pixel) |
Other functions | Save waveform data in real time to the CF card or USB memory stick, Numerical value calculations, Waveform calculations, and others |
AC Power | Using the AC ADAPTER 9418-15 (100 to 240 V AC, 50/60 Hz), 7 VA |
DC Power | Using the BATTERY PACK Z1000 (optional accessory), Continuous use 5 hr, External power: 10 to 28 V DC (Please contact your HIOKI distributor for connection cord) |
Dimensions & Mass | 272 mm (10.71 in) W ¡¿ 182.4 mm (7.18 in) H ¡¿ 66.5 mm (2.62 in) D, 1.8 kg (63.5 oz), (LR8400-20 main unit, excluding the Battery Pack 370 g/ 13.1 oz) |
Accessories | Detailed operating manual ¡¿1, Measurement guide ¡¿1, AC ADAPTER 9418-15 ¡¿1, USB cable ¡¿1, CD-R (data collection software "Logger Utility") ¡¿1 |