52³â È÷¿ÀÅ° Çѱ¹À¯Åë ŽŻó»ç
|
|
HOME > Á¦Ç°¼Ò°³ > Á¦Ç°Á¤º¸
|
|
|
|
|
|
| | | ¹«°ÔºÒ°ú 60 g, µÎ²² 9.5mmÀÇ Ä«µå »çÀÌÁî | | | Ç® ¿ÀÅä ·¹ÀÎÁö·Î ¿ÀÅä ÆÄ¿ö¼¼À̺ê±â´É ÷ºÎ | | | ¥Ø/µµÅë·¹ÀÎÁö´Â AC250 V±îÁö °úÀü¾Ð º¸È£ | | |
|
|
|
| | | Á÷·ù Àü¾Ð : 420m/4.2/42/420/500V(¡¾0.7%rdg.¡¾4dgt./4.2V) | | | ±³·ù Àü¾Ð : 4.2/42/420/500V(¡¾2.3%rdg.¡¾8dgt./50¡500Hz) | | | ÀúÇ× : 420/4.2k/42k/420k/4.2M¥Ø/42M¥Ø (¡¾2%rdg.¡¾4dgt./420¡420k¥Ø) | | | °³¹æ ´ÜÀÚ Àü¾Ð : ¾à 3.4V(420¥Ø), ¾à 0.5V(42k¡42M¥Ø), ¾à 3.4V(µµÅë) | | | µµÅë : 50¥Ø¡¾40¥Ø ÀÌÇÏ·Î(¿¡¼) ¹öÀúÀ½ | | | »ùÇà ·¹ÀÌÆ® : 2.5ȸ/s | | | Àü¿ø : µ¿ÀüÇü¸®Æ¬ ÀüÁö(CR2032)¡¿1/¿¬¼Ó »ç¿ë¾à 150h | | | Ä¡¼ö¡¤Áú·® : 55W¡¿109H¡¿9.5D mm¡¤60g | |
| DC Voltage range | 420 mV to 500 V, 5 ranges, Best accuracy: ¡¾0.7 % rdg. ¡¾4 dgt. | | AC Voltage range | 4.2 V to 500 V, 4 ranges, Accuracy: ¡¾2.3 % rdg. ¡¾8 dgt. , Average rectifier effective value | | Frequency characteristics at AC Voltage | 50 to 500 Hz | | Resistance range | 420 ohm to 42 M-ohm, 6 ranges, Best accuracy: ¡¾2.0 % rdg. ¡¾4 dgt. | | Continuity | Possible 50 ohm ¡¾40 ohm | | Auto power save | Possible (Cancel possible) | | Range switching | Auto | | Display | Digital/LCD, maximum 4199 dgt. | | Sampling rate | 2.5 times/sec | | Safety considerations | Safety: EN61010-1 : 1993, Pollution degree 2, over voltage category II, EMC: EN61326-1 : 1997 + A1 : 1998 | | Power supply | CR2032 ¡¿ 1 batterie, (Continuous use 150 hours) | | Dimensions, mass | 55 mm(2.17 in)W ¡¿ 109 mm(4.29 in)H ¡¿ 9.5 mm(0.37 in)D, 60 g (2.1 oz) | | Accessories | Instruction Manual¡¿1, Carrying case¡¿1, Coin type litium battery(CR2032)¡¿ 1 (for trial purposes only), Sleeves (Red/ Black each 1) |
|
|
|
|
|
|
|
|
|
|