• ½ÅÁ¦Ç°
  • Á¦Ç°¼Ò°³
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
    • ½ÅÈ£¹ß»ý±â
    • ȯ°æÃøÁ¤±â
    • Ŭ·¥ÇÁ¼¾¼­
    • ÇöÀå¿ë Å×½ºÅͱâ
    • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
    • °Å¸®ÃøÁ¤±â
    • ÁÖº¯Àåºñ/¿É¼Ç
    • PCB °Ë»çÀåºñ-ATEÀåºñ
  • ±â¼úÀÚ·á
    • Ä«´Þ·Î±×
    • ¸Þ´º¾ó
    • ¼ÒÇÁÆ®¿þ¾î
  • Àû¿ë»ç·Ê
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • LCR ¹ÌÅÍ
    • ÀúÀúÇ×°è
    • ±âŸ
  • °í°´¼¾ÅÍ
    • °øÁö»çÇ×
    • °ßÀû¿äû
    • A/S ¼¾ÅÍ
    • Á¦Ç° ¹®ÀÇ
    • 1:1 Ä£Àý »ó´ã
    • ¸Þ´º¾ó »ó´ã
    • Á¤Ç°È®ÀÎ
    • FAQ
    • Contact Us
  • ä¿ëÁ¤º¸
    • ä¿ë°ø°í
  • ȸ»ç¼Ò°³
    • Àλ縻
    • ȸ»çÁ¶Á÷µµ
    • ȸ»ç À§Ä¡ ¹× ¿µ¾÷¼Ò
    • ISO 9001 Á¤º¸
  • ·¹ÄÚ´õ
  • Àü·Â°è
  • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
  • ½ÅÈ£¹ß»ý±â
  • ȯ°æÃøÁ¤±â
  • Ŭ·¥ÇÁ¼¾¼­
  • ÇöÀå¿ë Å×½ºÅͱâ
  • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
  • °Å¸®ÃøÁ¤±â
  • ³»Àü¾ÐÃøÁ¤±â
  • ÁÖº¯Àåºñ/¿É¼Ç
  • PCB °Ë»çÀåºñ-ATEÀåºñ





52³â È÷¿ÀÅ° Çѱ¹À¯Åë ŽŻó»ç
HOME > Á¦Ç°¼Ò°³ > Á¦Ç°Á¤º¸


PW9100
±¤´ë¿ªÀÇ °íÁ¤È®µµ Àü·ù °èÃøÀ» ½ÇÇö
Á¦Ç°¹øÈ£ : PW9100
Á¦ Ç° ¸í  : AC/DC CURRENT BOX
Á¦Ç°ºÐ·ù : ¿É¼Ç/ÁÖº¯ÀåÄ¡
 
  
 
 
50A Á¤°ÝÀ¸·Î ¼¼°èÃÖ°í Ŭ·¡½ºÀÇ ÃøÁ¤ ´ë¿ª°ú ÃøÁ¤ È®µµ¸¦ ½ÇÇö
DC ~3.5MHzÀÇ ³ÐÀº ÁÖÆļö ´ë¿ª
PW6001°úÀÇ Á¶ÇÕ, Àü·Â È®µµ ¡¾0.075%
CMRR(µ¿»ó ½ÅÈ£ Á¦°Åºñ) 120dB(100kHz)
½ÃÇè/º¥Ä¡ Æò°¡¿¡µµ ´ëÀÀ °¡´ÉÇÑ Full-rack size
PW6001/3390/3390-10°ú Á¶ÇÕ °¡´É
 
  Measurement line type Isolated input, DCCT input
  Rated primary current 50 A AC/DC
  Number of input channels PW9100-03: 3 channels
PW9100-04: 4 channels
  Maximum input current Voltage: ¡¾42 V peak (AC + DC)
Current: 0.15 A rms (¡¾0.15 A DC)
  Maximum input current 60 A, within derating. However, up to ¡¾200 A peak is allowable if within 20 ms (design value)
  Amplitude and Phase accuracy DC (¡¾0.02 % rdg. ¡¾0.007 % f.s.)
45 Hz < f ¡Â 65 Hz (¡¾0.02 % rdg. ¡¾0.005 % f.s., Phase: ¡¾0.1 deg.)
Accuracy is defined to 1 MHz
  Output voltage 2 V/50 A
  Measurement terminals Terminal block (with safety cover), M6 screws
  Input resistance 1.5 m¥Ø or less (50 Hz/60 Hz)
  Operating temperature and humidity Temperature: 0¡ÆC to 40¡ÆC (32¡ÆF to 104¡ÆF), Humidity: 80% RH or less (no condensation)
  Power supply Power supply from PW6001, 3390, 3390-10
  Dimensions and mass 430 mm (16.93 in) W ¡¿ 88 mm (3.46 in) H ¡¿ 260 mm (10.24 in) D, Cable length: 0.8 m (2.62 ft)
PW9100-03: 3.7 kg (130.5 oz), PW9100-04: 4.3 kg (151.7 oz)
  Accessories Instruction Manual ¡¿1





Conversion & Extension Cable

CONVERSION CABLE
CT9901


EXTENSION CABLE
CT9902

 