• ½ÅÁ¦Ç°
  • Á¦Ç°¼Ò°³
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
    • ½ÅÈ£¹ß»ý±â
    • ȯ°æÃøÁ¤±â
    • Ŭ·¥ÇÁ¼¾¼­
    • ÇöÀå¿ë Å×½ºÅͱâ
    • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
    • °Å¸®ÃøÁ¤±â
    • ÁÖº¯Àåºñ/¿É¼Ç
    • PCB °Ë»çÀåºñ-ATEÀåºñ
  • ±â¼úÀÚ·á
    • Ä«´Þ·Î±×
    • ¸Þ´º¾ó
    • ¼ÒÇÁÆ®¿þ¾î
  • Àû¿ë»ç·Ê
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • LCR ¹ÌÅÍ
    • ÀúÀúÇ×°è
    • ±âŸ
  • °í°´¼¾ÅÍ
    • °øÁö»çÇ×
    • °ßÀû¿äû
    • A/S ¼¾ÅÍ
    • Á¦Ç° ¹®ÀÇ
    • 1:1 Ä£Àý »ó´ã
    • ¸Þ´º¾ó »ó´ã
    • Á¤Ç°È®ÀÎ
    • FAQ
    • Contact Us
  • ä¿ëÁ¤º¸
    • ä¿ë°ø°í
  • ȸ»ç¼Ò°³
    • Àλ縻
    • ȸ»çÁ¶Á÷µµ
    • ȸ»ç À§Ä¡ ¹× ¿µ¾÷¼Ò
    • ISO 9001 Á¤º¸
  • ·¹ÄÚ´õ
  • Àü·Â°è
  • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
  • ½ÅÈ£¹ß»ý±â
  • ȯ°æÃøÁ¤±â
  • Ŭ·¥ÇÁ¼¾¼­
  • ÇöÀå¿ë Å×½ºÅͱâ
  • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
  • °Å¸®ÃøÁ¤±â
  • ³»Àü¾ÐÃøÁ¤±â
  • ÁÖº¯Àåºñ/¿É¼Ç
  • PCB °Ë»çÀåºñ-ATEÀåºñ





52³â È÷¿ÀÅ° Çѱ¹À¯Åë ŽŻó»ç
HOME > Á¦Ç°¼Ò°³ > Á¦Ç°Á¤º¸


CT7040S
600A/6000A, 3Á¾·ùÀÇ FLEXIBLE SENSOR
Á¦Ç°¹øÈ£ : CT7040S
Á¦ Ç° ¸í  : AC FLEXIBLE CURRENT SENSOR
Á¦Ç°ºÐ·ù : Ŭ·¥ÇÁ¼¾¼­
 
  
 
 
Á¼Àº °ø°£À̳ª º¹ÀâÇÑ ¹è¼±¿¡µµ »ç¿ëÇϱ⠽¬¿î ½½¸² ÄÉÀ̺í ŸÀÔ
6000AÀÇ ´ëÀü·ù °èÃø¿¡µµ ´ëÀÀ
10Hz ~ 50kHzÀÇ ÁؼöÇÑ ÁÖÆļö ´ë¿ª
¿ëµµ¿¡ ¸Â°Ô °í¸¦ ¼ö ÀÖ´Â 3Á¾·ùÀÇ ÃøÁ¤ °¡´É µµÃ¼ Á÷°æ
µð½ºÇ÷¹ÀÌ À¯´Ö CM7290°ú Á¶ÇÕÇÏ¿© ÇöÀå¿¡¼­ ¼Õ½±°Ô ÃøÁ¤°ª È®ÀÎ °¡´É
¸Þ¸ð¸® ÇÏÀÌÄÚ´õ/·Î°ÅÀÇ ¿ëµµ¿¡ µû¶ó 4Á¾·ùÀÇ Ãâ·ÂÀÌ °¡´É(WAVE, PEAK, RMS, FREQUENCY)
CAT IV 600V, CAT III 1000V
 
[Á÷°æ¿¡ µû¸¥ ¸ðµ¨ ±¸ºÐ]
CT7046 : ¥õ254 mm (10.00 in)
CT7045 : ¥õ180 mm (7.09 in)
CT7044 : ¥õ100 mm (3.94 in)
 

  Sensor CT7046 CT7045 CT7044
  Rated measurement current 6000A AC
  Internal Measurement range 600A AC/ 6000A AC (Range is controlled by main device)
  Max. allowable input 10000 A continuous (at 6000 A range, 45 to 66 Hz, requires derating )
  Bandwidth 10 Hz to 50 kHz (¡¾3dB)
  Amplitude and phase accuracy ¡¾1.5 % rdg. ¡¾0.25 % f.s. (f.s. is internal range, 45 to 66 Hz) ¡¾1 deg
  Output rate 1 mV/A (600 A), 0.1 mV/A (6000 A)
  Max. rated voltage to earth AC 600 V (CAT IV), AC 1000 V (CAT III)
  Loop diameter ¥õ 254 mm (10.00 in) or less ¥õ 180 mm (7.09 in) or less ¥õ 100 mm (3.94 in) or less
  Dustproof
waterproof
IP54* (When sensor is connected to a compatible instrument.) * Do not use when wet.
  Output connectors HIOKI PL 14
  Dimensions Flexible loop cable diameter: ¥õ7.4 mm (0.29 in), Cable length: Between flexible loop
and battery box: 2.3 m (7.55 ft), Output cable: 20 cm (0.66 ft), Battery box25 mm (0.98 in)
W ¡¿ 72 mm (2.83 in)H ¡¿ 20 mm (0.79 in)D
  Mass 186 g (6.6 oz) 174 g (6.1 oz) 160 g (5.6 oz)
  Accessories N/A