• ½ÅÁ¦Ç°
  • Á¦Ç°¼Ò°³
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
    • ½ÅÈ£¹ß»ý±â
    • ȯ°æÃøÁ¤±â
    • Ŭ·¥ÇÁ¼¾¼­
    • ÇöÀå¿ë Å×½ºÅͱâ
    • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
    • °Å¸®ÃøÁ¤±â
    • ÁÖº¯Àåºñ/¿É¼Ç
    • PCB °Ë»çÀåºñ-ATEÀåºñ
  • ±â¼úÀÚ·á
    • Ä«´Þ·Î±×
    • ¸Þ´º¾ó
    • ¼ÒÇÁÆ®¿þ¾î
  • Àû¿ë»ç·Ê
    • ·¹ÄÚ´õ
    • Àü·Â°è
    • LCR ¹ÌÅÍ
    • ÀúÀúÇ×°è
    • ±âŸ
  • °í°´¼¾ÅÍ
    • °ßÀû¿äû
    • A/S ¼¾ÅÍ
    • Á¦Ç° ¹®ÀÇ
    • 1:1 Ä£Àý »ó´ã
    • ¸Þ´º¾ó »ó´ã
    • Á¤Ç°È®ÀÎ
    • FAQ
    • Contact Us
  • ä¿ëÁ¤º¸
    • ä¿ë°ø°í
  • ȸ»ç¼Ò°³
    • Àλ縻
    • ȸ»çÁ¶Á÷µµ
    • ȸ»ç À§Ä¡ ¹× ¿µ¾÷¼Ò
    • ISO 9001 Á¤º¸
  • ·¹ÄÚ´õ
  • Àü·Â°è
  • ȸ·Î¼ÒÀÚ ÃøÁ¤±â
  • ½ÅÈ£¹ß»ý±â
  • ȯ°æÃøÁ¤±â
  • Ŭ·¥ÇÁ¼¾¼­
  • ÇöÀå¿ë Å×½ºÅͱâ
  • ¾ÈÀü±Ô°Ý ÃøÁ¤±â
  • °Å¸®ÃøÁ¤±â
  • ³»Àü¾ÐÃøÁ¤±â
  • ÁÖº¯Àåºñ/¿É¼Ç
  • PCB °Ë»çÀåºñ-ATEÀåºñ





52³â È÷¿ÀÅ° Çѱ¹À¯Åë ŽŻó»ç
HOME > Á¦Ç°¼Ò°³ > Á¦Ç°Á¤º¸


CT6844 [´ÜÁ¾]
±¤´ë¿ª・°íÁ¤È®µµ ÃøÁ¤, ºÐÇÒÀü·ù¼¾¼­ 500A
Á¦Ç°¹øÈ£ : CT6844
Á¦ Ç° ¸í  : AC/DC CURRENT PROBE
Á¦Ç°ºÐ·ù : Ŭ·¥ÇÁ¼¾¼­
 
  
 
 
ÁøÆø È®µµ ¡¾0.3%, À§»ó È®µµ¡¾0.1ÀÇ °íÁ¤È®µµ ±¸Çö
DC ~ 100kHzÀÇ ³ÐÀº ÁÖÆļö ´ë¿ª
ÇѼÕÀ¸·Î Á¶ÀÛÀÌ °¡´É ¼ÒÇü »çÀÌÁî, Áøµ¿¿¡ °­ÇÑ lock ±â´É žÀç
µµÃ¼ À§»ó, ±ÙÁ¢ µµÃ¼, ÀÚ±âÀåÀÇ ¿µÇâÀ» ±âÁ¸Ç° ´ëºñ °æ°¨
ÀÚµ¿Â÷ ¹èÅ͸®ÀÇ ¼öÁö ÃøÁ¤, ÀιöÅÍ º¯È¯ È¿À² Æò°¡ µî¿¡ È°¿ë
 
[´ÜÀÚ Çüź° ¸ðµ¨ ±¸ºÐ]
CT6844 : AC/DC 500A
CT6844-05: AC/DC 500A, 12pin ´ÜÀÚ
 

  Rated current 500A AC/DC
  Max. allowable input 720A DC(requires derating)
  Frequency
characteristics
DC to 200 kHz
Phase: DC to 200 kHz
  Amplitude and
phase accuracy
DC ¡¾0.3 % rdg. ¡¾0.02 % f.s. (Phase: Not defined)
DC < f ¡Â 100 Hz ¡¾0.3 % rdg. ¡¾0.01 % f.s. (Phase: ¡¾0.1 deg)
Defined to 200 kHz
  Power consumption 7 VA max. (at 500 A/55 Hz, ¡¾12 V power requirement)
  Output voltage 4 mV/A (voltage output with the Sensor Unit 9555-10, use with a device having
a 1 M¥Ø input resistance or higher)
  Core diameter ¥õ 20 mm (1.79 in)
  Operating temperature, humidity -40 ¡ÆC to +85 ¡ÆC (-40 ¡ÆF to 185 ¡ÆF), 80% rh or less (with no condensation)
  Power supply DC ¡¾11 V to ¡¾15 V (Power suppled via the 9555-10, which supports 100 to 240 V AC)
  Dimension and Mass 153 mm (6.02 in)W ¡¿ 67 mm (2.64 in)H ¡¿ 25 mm (0.98 in)D
cord length: 3 m (9.84 ft), 380 g (13.4 oz)
  Accessories Instruction manual ¡¿1, Mark bands ¡¿6, Carrying Case¡¿1

  Compatible models CT6844 Combination status CT6844-05 Combination status
  Model 3390 OK ¡â(Requires Conversion Cable CT9901)
  Model PW6001 ¡â (Requires Conversion Cable CT9900) OK
  Input unit 9602 for 3193-10/ 3193/ 3194 OK (In combination, recognized as 500A AC/DC) ¡â (In combination, recognized as 500A AC/DC, requires Conversion Cable CT9901)
  Model 8971 for the MR8847-01s ¡â (In combination, recognized as 9279 [500 A rated], requires Conversion Cable 9318)
Maximum number of connectable sensors
when using MR8827 or MR8847-51/52/53: 5
¡â (In combination, recognized as 9279 [500 A rated], requires Conversion Cable 9318 & CT9901)
Maximum number of connectable sensors
when using MR8827 or MR8847-51/52/53: 5
  Model 8940 for the Memory Hicorders ¡â (In combination, recognized as 500A AC/DC, requires Conversion Cable 9705 and 9318) ¡â (Requires Conversion Cable 9705, 9318 and CT9901)





Options

CONNECTION CORD
9165


CONNECTION CORD(BNC-BNC)
L9217


¿¬Àå ÄÉÀ̺í
9706


CONVERSION CABLE
CT9900


CONVERSION CABLE
CT9901


EXTENSION CABLE
CT9902


º¯È¯ ÄÉÀ̺í
9705


CONVERSION CABLE
9318

 


¼­¿ï½Ã ±¸·Î±¸ °æÀηΠ53±æ 15, ¾÷¹«Aµ¿ 305-1È£ (±¸·Îµ¿, Áß¾ÓÀ¯Åë»ó°¡)  T. 02-3474-0070  F. 02-3474-0090

COPYRIGHT ¨Ï TAISHIN CO.LTD ALL RIGHTS RESERVED.

HIOKI ·Î°í & ISO9001 ÀÎÁõ¾÷ü ·Î°í